Liebert GXT - MT UPS, UPS Systems, UPS Batteries, Double Conversion UPS, Industrial Inverters, Mumbai, India
UNIBEST POWER
Liebert GXT - MT UPS, UPS Systems, UPS Batteries, Double Conversion UPS, Industrial Inverters, Mumbai, India
HOME PRODUCT PROFILE CONTACT FEEDBACK

SOLUTION
::OUR PRODUCT RANGE ::
Liebert GXT-MT 6/10 kVA UPS
Liebert GXT-MT 1-3 kVA UPS
Liebert ITON 600 UPS
Liebert ITON 1000 UPS
POWER BANK(6 kVA) UPS
Liebert SUPER 400D(10/20kVA) UPS

-------------------------------------------
Liebert GXT - MT UPS, UPS Systems, UPS Batteries, Double Conversion UPS, Industrial Inverters, Mumbai, India
139,Shanti Industrial Estate,
S. N. Road, Mulund (West),
Mumbai - 400 080,
Maharashtra, India.
Ph.No.: 25649590 / 92 / 93.
Fax. 25649594.
Email :
response@unibestpowersolutions.com
 


Liebert GXT - MT 6 / 10 kVA UPS

 
FIT AND FORGET UPS SYSTEM
POWER PROTECTION AND POWER SOURCE
Liebert GXT-MT 6 / 10 KVA UPS
True Online Double Conversion UPS
With Extended Runtime Capabilities

Features :
   
   
Parallel up to 3modules
Extended Runtime Capabilities
Compact Tower design
Generator Compatible
Class B Electromagnetic interference (EMC)
compatible (EN50091-2)
Ultra wide input voltage range
High capacity Battery Charger for GXTL
High input power factor & low THDi
   
 
Applications
Small & Medium Size Data Center
Telecommunication, VoIP
Office Network
Data Warehouses
Process Automation Equipments

Specification

Electrical
Model   GXT6000L-MT GXT10000L-MT
Rating   6000VA/4200W 10000VA/7000W
Input Input system 1-phase, plusPE
Rated voltage
22OVac
Voltage range
180-270 V
Frequency
50 Hz
Power factor > 0.98 (conditions: rated voltage, full pure resistive load, fully charged battery)
Input THDi
<10%
Frequency range
46-54 Hz
Output Output system 1-phase, plusPE
Power factor
0.7
Voltage
220Vac/230Vac/240Vac±l%
Line regulation
<l%(0~100% linear load)
Voltage harmonic distortion (rated input voltage, rated input frequency) <2%(0 "100% linear load) < 6%(0 "100% non-linear load)
Dynamic variation
±5% in 60 ms
Frequency

50/60Hz±0.05Hz
Inverter overload capability (in Normal mode, 25"C)
105%~130% lOmin, transfer to bypass >130% 1 sec. transfer to bypass turnoff output
Inverter overload capability (in Battery mode, 25-C)
>105% lOsec,
Crest factor
3:1
Bypass Auto retransfer
Yes
Transfer time
Normal<->Battery: 0ms
Communication Port
RS 232 as standard
External battery voltage
240Vdc
Charging current 4.2A
Battery Capacity 20nos.ofl2V
Charging duration Depends on battery capacity
Noise (within 1 m) <55db
Protection IP20(static state)
Operating Temperature 0-40°C
Installation Height <1000m
Relative Humidity <95%
Dimension (WxDxH) 260mmx570mmx717mm
Weight 6kVA/90kg 10kVA/93kg
     
TOP
  HOME | PRODUCT | PROFILE | CONTACT | FEEDBACK  
Best View : 1024 X 768 Pixels Designed & Hosted By : MID   Promoted By : GID